Chamber volume: 131 L stainless steel (SS304)
Temperature range: Room temperature +10°C to 200°C
Temperature control accuracy: ±1°C; uniformity: ±2°C
Dimensions (W×D×H): 450×540×540 mm interior
Power: 208–240 VAC, 50/60 Hz, 2200 W max

규정 준수: CE 인증 획득
맞춤형: OEM/ODM
포장: 합판 케이스 포장

제품

MSK-TE909 Battery Thermal Abuse Test Chamber with 131 L Stainless Steel Chamber, Programmable Heating to 200°C, and Optional Automatic Fire Extinguisher Fixtures

The MSK-TE909 is engineered to conduct precise thermal abuse testing on batteries, simulating elevated temperature conditions to assess safety and performance in compliance with IEC 62133 Section 8.2.2. This chamber is ideal for laboratories requiring controlled heating environments up to 200°C with high accuracy and uniformity, enabling reliable evaluation of battery behavior under thermal stress.

Operating on a single-phase 208–240 VAC power supply, the chamber features a spacious 131-liter interior constructed from corrosion-resistant SS304 stainless steel. The working area measures 450 mm wide by 540 mm deep and 540 mm high, accommodating various battery sizes on two removable steel racks. An observation window made of high-temperature glass with anti-explosion film allows safe visual monitoring during tests. The chamber includes cable feedthrough ports and a pressure-relief opening to maintain safety during thermal events.

주요 기능

  • Programmable digital temperature controller with 30 segments for customized heating profiles
  • Temperature control accuracy of ±1°C and uniformity within ±2°C in the working area
  • Maximum heating rate of 7°C per minute for efficient thermal cycling
  • Two 50 mm diameter side ports for electrical wiring and fire-suppression tubing
  • Rear 150 mm diameter pressure-relief port and 32 mm ventilation opening for safety and hot-air exhaust
  • Optional fire-suppression systems: automatic nitrogen gas discharge, separate automatic extinguisher fixture, or combined configuration
  • Compliance with IEC 62133 Section 8.2.2 for battery safety testing

기술 사양

모델 MSK-TE909
Product Type Battery Thermal Abuse Test Chamber
Test Standard Reference IEC 62133, Section 8.2.2 (confirm edition before use)
Working Voltage 208–240 VAC, 50/60 Hz, single-phase
Maximum Power 2200 W
Chamber Interior Material SS304 stainless steel
Interior Dimensions (W×D×H) 450 × 540 × 540 mm
Chamber Volume 131 L
온도 범위 Room temperature +10°C to 200°C
Temperature Control Accuracy ±1°C
온도 균일도 ±2°C
Maximum Heating Rate 7°C/min
Observation Window 200 × 300 mm high-temperature glass with anti-explosion film
Ports Two 50 mm diameter side ports; one 150 mm diameter rear pressure-relief port; one 32 mm diameter rear ventilation opening
Sample Racks Two removable steel racks included
Working Environment Ambient 25 ± 3°C, 30–90% RH, low vibration and electromagnetic interference

대표적인 적용 분야

This chamber is suited for battery manufacturers, research labs, and safety testing facilities conducting thermal abuse tests to evaluate battery safety performance under controlled high-temperature conditions. It supports testing of single cells and battery packs within specified capacity limits, aiding compliance with international safety standards.

구성 및 작동 안내

The MSK-TE909 includes two removable steel racks for sample placement; batteries must be placed on these racks and never directly on the chamber floor to avoid damage. The chamber’s programmable controller allows up to 30 heating segments with built-in alarms for over-temperature and thermocouple failure.

Optional fire-suppression systems are available at additional cost and must be selected based on battery chemistry, energy capacity, and test hazards. Options include an automatic nitrogen gas suppression fixture, a separate automatic fire extinguisher fixture, or a combined system. Users must ensure proper ventilation and emergency response plans when using nitrogen suppression due to oxygen deficiency risks.

Shipping Information

The chamber weighs approximately 149.5 lb (67.8 kg) when equipped with the nitrogen extinguishing fixture option. Shipping dimensions and weight vary with configuration and should be confirmed prior to order.