MSK-TE909-Prüfkammer für thermische Überbeanspruchung von Batterien mit einer 131-Liter-Edelstahlkammer, programmierbarer Beheizung auf 200 °C und optionalen Halterungen für automatische Feuerlöscher
The MSK-TE909 is engineered to conduct precise thermal abuse testing on batteries, simulating elevated temperature conditions to assess safety and performance in compliance with IEC 62133 Section 8.2.2. This chamber is ideal for laboratories requiring controlled heating environments up to 200°C with high accuracy and uniformity, enabling reliable evaluation of battery behavior under thermal stress.
Operating on a single-phase 208–240 VAC power supply, the chamber features a spacious 131-liter interior constructed from corrosion-resistant SS304 stainless steel. The working area measures 450 mm wide by 540 mm deep and 540 mm high, accommodating various battery sizes on two removable steel racks. An observation window made of high-temperature glass with anti-explosion film allows safe visual monitoring during tests. The chamber includes cable feedthrough ports and a pressure-relief opening to maintain safety during thermal events.
Wichtigste Merkmale
- Programmable digital temperature controller with 30 segments for customized heating profiles
- Temperature control accuracy of ±1°C and uniformity within ±2°C in the working area
- Maximum heating rate of 7°C per minute for efficient thermal cycling
- Two 50 mm diameter side ports for electrical wiring and fire-suppression tubing
- Rear 150 mm diameter pressure-relief port and 32 mm ventilation opening for safety and hot-air exhaust
- Optional fire-suppression systems: automatic nitrogen gas discharge, separate automatic extinguisher fixture, or combined configuration
- Compliance with IEC 62133 Section 8.2.2 for battery safety testing
Technische Daten
| Modell | MSK-TE909 |
|---|---|
| Produkttyp | Battery Thermal Abuse Test Chamber |
| Test Standard Reference | IEC 62133, Section 8.2.2 (confirm edition before use) |
| Betriebsspannung | 208–240 VAC, 50/60 Hz, single-phase |
| Maximale Leistung | 2200 W |
| Chamber Interior Material | Edelstahl SS304 |
| Interior Dimensions (W×D×H) | 450 × 540 × 540 mm |
| Kammervolumen | 131 L |
| Temperaturbereich | Room temperature +10°C to 200°C |
| Genauigkeit der Temperaturregelung | ±1 °C |
| Temperaturgleichmäßigkeit | ±2°C |
| Maximum Heating Rate | 7°C/min |
| Sichtfenster | 200 × 300 mm high-temperature glass with anti-explosion film |
| Ports | Two 50 mm diameter side ports; one 150 mm diameter rear pressure-relief port; one 32 mm diameter rear ventilation opening |
| Sample Racks | Two removable steel racks included |
| Working Environment | Ambient 25 ± 3°C, 30–90% RH, low vibration and electromagnetic interference |
Typische Anwendungsbereiche
This chamber is suited for battery manufacturers, research labs, and safety testing facilities conducting thermal abuse tests to evaluate battery safety performance under controlled high-temperature conditions. It supports testing of single cells and battery packs within specified capacity limits, aiding compliance with international safety standards.
Hinweise zur Konfiguration und zum Betrieb
The MSK-TE909 includes two removable steel racks for sample placement; batteries must be placed on these racks and never directly on the chamber floor to avoid damage. The chamber’s programmable controller allows up to 30 heating segments with built-in alarms for over-temperature and thermocouple failure.
Optional fire-suppression systems are available at additional cost and must be selected based on battery chemistry, energy capacity, and test hazards. Options include an automatic nitrogen gas suppression fixture, a separate automatic fire extinguisher fixture, or a combined system. Users must ensure proper ventilation and emergency response plans when using nitrogen suppression due to oxygen deficiency risks.
Versandinformationen
The chamber weighs approximately 149.5 lb (67.8 kg) when equipped with the nitrogen extinguishing fixture option. Shipping dimensions and weight vary with configuration and should be confirmed prior to order.