MSK-HTML-SLA16 Automatic Electrolyte Preparation and 16-Channel Coin Cell Assembling System for Battery R&D
The MSK-HTML-SLA16 addresses the need for efficient and reproducible electrolyte formulation and coin cell fabrication in battery research laboratories. It enables researchers to explore novel electrolyte compositions by automating the preparation of liquid and powder components and assembling coin cells for performance evaluation.
This integrated system combines a multi-source electrolyte preparation module with a 16-channel coin cell assembly line. The electrolyte preparation supports six liquid solutions (three main at 1000 mL and three auxiliary at 500 mL) and five powder types (each 300 mL), allowing up to 48 distinct electrolyte recipes. Magnetic stirring ensures homogeneity, while precise syringe pumps and powder dispensing modules provide accurate dosing.
Key Features
- Automated electrolyte preparation with six liquid and five powder inputs for up to 48 recipes.
- Magnetic stirring unit capable of stirring four samples simultaneously for uniform mixing.
- Six-axis and four-axis robot arms for precise sample and container handling.
- Six precise syringe pumps for liquid dosing and five powder dispensing modules with ±2.5 mg accuracy.
- 16-channel automatic coin cell assembly with pre-loaded components and ±2 μL accuracy electrolyte filling.
- Glovebox environment maintaining O2 and H2O levels below 5 ppm for sensitive operations.
- Sample preparation efficiency of one sample per 30 minutes (excluding stirring time).
Technical Specifications
| Parameter | Specification |
|---|---|
| Power Supply | AC 220V ±10%, 50/60 Hz, single phase, total 5 kW (excluding glovebox) |
| Robot Arms | One six-axis + one four-axis |
| Liquid Samples | 6 types (3 main at 1000 mL, 3 auxiliary at 500 mL) |
| Powder Samples | 5 types, each 300 mL |
| Electrolyte Recipes | Up to 48 recipes, max 50 mL each |
| Liquid Addition | Six precise syringe pumps |
| Powder Addition | Five solid powder modules with ±2.5 mg accuracy |
| Sample Preparation Rate | One sample per 30 minutes (excluding stirring) |
| Stirring Method | Magnetic stirring, four samples simultaneously |
| Coin Cell Assembly Channels | 16 channels |
| Electrolyte Filling Accuracy | ±2 μL via syringe |
| Glovebox Atmosphere | O2 and H2O ≤ 5 ppm |
Typical Applications
This system is ideal for battery R&D labs focused on developing and testing new electrolyte formulations and assembling coin cells for electrochemical performance evaluation. It supports high-throughput screening of electrolyte recipes and consistent cell fabrication under controlled atmosphere.
Configuration & Operating Notes
The system includes powder dispensing, liquid feeding, magnetic stirring, electrolyte filling, coin cell crimping, and cap tightening/removing units. The six-axis robot arm handles sample and container transport. Components such as coin cell parts must be pre-loaded. The glovebox environment ensures low moisture and oxygen levels critical for battery materials. Operators should follow safety protocols for handling powders and liquids and maintain glovebox atmosphere for optimal results.
Dimensions & Shipping
| Product dimensions | L6500*W1200*H1700mm |
|---|