Kategorie

Kontaktieren Sie uns

VBF1200XVGB Glovebox-Compatible Split-Type Vertical Furnace with Quartz Tube Chamber, 1100°C Max Temperature

Designed for heat treatment of moisture- and oxygen-sensitive materials, compatible with glovebox integration.
Features a sealed quartz tube chamber and split-type design for external control operation.
Maximum heating temperature of 1100°C with PID automatic temperature control.
Includes stainless steel sample racks and crucibles; recommended argon or nitrogen atmosphere.

Konformität: CE-zertifiziert
Maßgeschneidert: OEM/ODM
Verpackung: Sperrholzkiste

Produkte

VBF1200XVGB Glovebox-Compatible Split-Type Vertical Furnace with Quartz Tube Chamber, 1100°C Max Temperature

The VBF1200XVGB is engineered for precise heat treatment of materials that are highly sensitive to moisture and oxygen exposure. Its vertical well furnace design allows direct connection to a glovebox via a KF200 flange, enabling seamless transfer of samples under controlled inert atmospheres such as argon or nitrogen. This integration facilitates uninterrupted processing workflows for sensitive samples immediately after thermal treatment.

The furnace features a sealed single-end closed quartz tube chamber (φ200 × 340 mm) that acts as the reaction environment, surrounded by a high-purity alumina fiber insulation with imported high-temperature alumina coating. The split-type configuration separates the control box from the furnace body, allowing operation outside the glovebox for user convenience and safety.

Wichtigste Merkmale

  • Maximum heating temperature of 1100°C with continuous operation up to 1000°C and holding time ≤30 minutes at peak temperature.
  • Quartz tube sealed chamber with stainless steel water-cooled sealing flange and fluororubber O-ring for airtight operation.
  • PID automatic temperature control via 858 series controller with 50 programmable segments and ±1°C accuracy.
  • Gas inlet and outlet system equipped with compression fittings, ball valve, and stainless steel needle valve for controlled atmosphere management.
  • Includes three-layer perforated stainless steel rack and stainless steel crucible for sample placement.
  • Recommended inert gases: argon or nitrogen supplied from a 40 L cylinder with pressure regulator and PTFE tubing.
  • Split-type design enhances operational flexibility by separating control electronics from the furnace chamber.

Technische Daten

Parameter Spezifikation
Stromversorgung AC 220V, 50/60Hz
Rated Power 3.8 kW
Circuit Breaker Requirement ≥25A air switch / circuit breaker
Grounding Resistance <4Ω
Maximum Heating Temperature 1100°C
Maximum Holding Time at 1100°C ≤30 minutes
Continuous Operating Temperature 1000°C
Recommended Heating Rate ≤10°C/min
Heating Zone Size Φ240 × 260 mm
Heating Element Resistance wire
Thermoelementtyp Typ K
Furnace Chamber Material High-purity alumina fiber with imported alumina coating
Sealed Chamber Single-end closed quartz tube (Φ200 × 340 mm)
Flange Type Stainless steel water-cooled sealing flange with fluororubber O-ring
Glovebox Connection KF200 flange
Gas Inlet Port Φ6.35 mm compression fitting with Φ7 mm bore ball valve
Gas Outlet Port Φ6.35 mm compression fitting with stainless steel needle valve
Internal Gas Guide Quartz gas inlet tube extending to chamber bottom
Recommended Working Gas Argon or nitrogen
Sample Holder Three-layer perforated stainless steel rack (Φ145 × 205 mm), stainless steel crucible (Φ115 × 40 mm)
Temperaturregler 858 series PID controller with 50 programmable segments, ±1°C accuracy
Protection Functions Over-temperature protection, thermocouple failure alarm
Communication Port DB9 PC communication port (default)
Design Split-type with control box separated from furnace body

Typische Anwendungsbereiche

This furnace is ideal for thermal processing of materials that require strict exclusion of moisture and oxygen, such as advanced battery materials, sensitive catalysts, and air-sensitive chemical compounds. Its glovebox compatibility allows direct sample transfer without atmospheric exposure, supporting research and production workflows in materials science and chemical synthesis.

Hinweise zur Konfiguration und zum Betrieb

The furnace requires connection to an external water chiller (recommended model: KJ-5300) for the water-cooled sealing flange. The chiller is not included and must be procured separately. Proper grounding and circuit protection per specifications are essential for safe operation. Gas supply must be regulated with appropriate pressure regulators and PTFE tubing. Optional PC software is available for advanced temperature programming and data export. Users should ensure all seals and connections are properly maintained to preserve the inert atmosphere integrity.

Produktbezogene Informationen

MSK-AFA-H200A laboratory product view 1
OTF-1600X-UL laboratory product view 1
SE-KTQ-250 laboratory product view 1
HP1515 laboratory product view 1
Zum Seitenanfang scrollen